0

    Autosampler Tubes & Cups

    For Flame Continuous Method

    P/N Description Applicable Model
    046-00147-04 Test tube,
    15 mL, φ 16 x 100
    ASC-7000
    ASC-6100
    200-93113-05 Glass sample cup,
    53 mL, φ 30 x 90
    046-00150-27 Glass test tube,
    12 mL
    ASC-7000

    For Furnace and Flame Micro Sampling Methods

    P/N Description Applicable Model
    038-00259-02 Sample tube,
    2 mL, φ 14 x 23.6
    ASC-7000
    ASC-6100
    038-00259-03 Sample tube,
    2 mL, φ 14 x 23.6, 50 pcs
    038-00155-03 Sample cup,
    20 mL, φ 28 x 48.5
    200-93036 200-93036 Glass sample cup,
    2 mL
    ASC-7000

    GFA Graphite Tubes

    In graphite furnace technology, it is important to select the graphite tube according to the target element and sample composition. Actually there is a wide variety of different graphite tubes used in electrothermal atomization. Shimadzu´s atomic absorption spectrometers can be operated with different tube types: high density graphite tube, pyrolytic coating graphite tube, a “fork”- platform graphite tube and last not least the omega platform tube.

     

     

    Hollow Cathode Lamps / High-Performance type

    High-Performance Boosted Hollow Cathode Lamp designed for AA-6880

    The AA-6880 lamp house has an 8 lamp turret with an automatic switching function, where the No. 7 and No. 8 lamp holders can be used for both an ordinary hollow cathode lamp and a high-performance boosted hollow cathode lamp. The AA-6880 can simultaneously light any two hollow cathode lamps.
    For the high-performance boosted hollow cathode lamp, an auxiliary cathode electrode is added based on two ordinary hollow cathode lamps. The atoms will be produced under the sputtering action in the hollow cathode due to discharging between the hollow cathode and the anode. The low-voltage high current between the anode and the auxiliary cathode provides excitation energy for the atoms, and such sputtering action and excitation action will be respectively controlled by two separate discharge processes. This greatly improves the excitation efficiency of the atomic spectrum. The high-performance hollow cathode lamp requires a dedicated power supply.
    The AA-6880 main unit has a built-in high-performance boosted hollow cathode lamp power supply. Two high-performance hollow cathode lamps can be simultaneously illuminated without any external power supply.
    An auxiliary cathode current can be automatically scanned, which only requires optimizing the test conditions.

    Main Features of High-Performance Boosted Hollow Cathode Lamps

    (Compared with Ordinary Lamps)

    • High emission intensity and good stability
    • High measurement sensitivity and low detection limit
    • Expanded calibration curve linear range
    • Reduced spectrum interference from adjacent lines, so a larger spectral bandwidth can be used to further improve the energy. In general, the electrodes of the high-performance boosted hollow cathode lamp, made by low-melting-point and volatile elements,such as As, Bi, Pb, Sb, Se, Zn, etc., show better application results.

     

     
    1. Comparison table for typical detection limits of the high-performance type and ordinary type hollow cathode lamp
    Element Air-Acetylene Flame Analysis Graphite Furnace Analysis
    Detection Limit (µg/mL) Detection Limit (pg)
    Ordinary type High-Performance type Ordinary type High-Performance type
    Pb 0.0279 0.0149 0.68 (10 µL) 0.42 (10 µL)
    Zn 0.0019 0.0010 0.055 (20 µL) 0.025 (20 µL)

    Product Information

    P/N Measured Element Element Symbol
    208-94046-01 Aluminum AL
    208-94046-02 Antimony SB
    208-94046-03 Arsenic AS
    208-94046-04 Beryllium BE
    208-94046-05 Bismuth BI
    208-94046-06 Boron B
    208-94046-07 Cadmium CD
    208-94046-08 Calcium CA
    208-94046-09 Chromium CR
    208-94046-10 Cobalt CO
    208-94046-11 Copper CU
    208-94046-12 Germanium GE
    208-94046-13 Gold AU
    208-94046-14 Iridium IR
    208-94046-15 Iron FE
    208-94046-16 Lead PB
    208-94046-17 Lutetium LU
    208-94046-18 Magnesium MG
    208-94046-19 Manganese MN
    208-94046-20 Molybdenum MO
    208-94046-21 Nickel NI
    208-94046-22 Palladium PD
    208-94046-23 Platinum PT
    208-94046-24 Rhodium RH
    208-94046-25 Ruthenium RU
    208-94046-26 Selenium SE
    208-94046-27 Silicon SI
    208-94046-28 Silver AG
    208-94046-29 Tantalum TA
    208-94046-30 Tellurium TE
    208-94046-31 Tin SN
    208-94046-32 Titanium TI
    208-94046-33 Tungsten W
    208-94046-34 Vanadium V
    208-94046-35 Zinc ZN
    208-94046-36 Zirconium ZR
    Hollow Cathode Lamps / Ordinary type

    Single-Element

    P/N Description Measured Element
    200-38422-02 Hollow cathode lamp, L233-47NU Ag
    200-38422-01 Hollow cathode lamp, L233-13NU Al
    200-38422-42 Hollow cathode lamp, L233-33NQ As
    200-38422-25 Hollow cathode lamp, L233-79NQ Au
    200-38422-39 Hollow cathode lamp, L233-5NQ B
    200-38422-03 Hollow cathode lamp, L233-56NB Ba
    200-38422-04 Hollow cathode lamp, L233-4NQ Be
    200-38422-43 Hollow cathode lamp, L233-83NQ Bi
    200-38422-05 Hollow cathode lamp, L233-20NU Ca
    200-38422-06 Hollow cathode lamp, L233-48NQ Cd
    200-38422-09 Hollow cathode lamp, L233-27NQ Co
    200-38422-07 Hollow cathode lamp, L233-24NU Cr
    200-38422-27 Hollow cathode lamp, L233-55NB Cs
    200-38422-08 Hollow cathode lamp, L233-29NU Cu
    200-38422-60 Hollow cathode lamp, L233-66NB Dy
    200-38422-61 Hollow cathode lamp, L233-68NB Er
    200-38422-62 Hollow cathode lamp, L233-63NB Eu
    200-38422-10 Hollow cathode lamp, L233-26NQ Fe
    200-38422-40 Hollow cathode lamp, L233-31NU Ga
    200-38422-63 Hollow cathode lamp, L233-64NB Gd
    200-38422-11 Hollow cathode lamp, L233-32NU Ge
    200-38422-64 Hollow cathode lamp, L233-72NU Hf
    200-38422-28 Hollow cathode lamp, L233-80NQ Hg
    200-38422-65 Hollow cathode lamp, L233-67NB Ho
    200-38422-48 Hollow cathode lamp, L233-49NB In
    200-38422-66 Hollow cathode lamp, L233-77NQ Ir
    200-38422-22 Hollow cathode lamp, L233-19NB K
    200-38422-29 Hollow cathode lamp, L233-57NU La
    200-38422-30 Hollow cathode lamp, L233-3NB Li
    200-38422-67 Hollow cathode lamp, L233-71NB Lu
    200-38422-12 Hollow cathode lamp, L233-12NU Mg
    200-38422-13 Hollow cathode lamp, L233-25NU Mn
    200-38422-31 Hollow cathode lamp, L233-42NU Mo
    200-38422-14 Hollow cathode lamp, L233-11NB Na
    200-38422-32 Hollow cathode lamp, L233-41NU Nb
    200-38422-68 Hollow cathode lamp, L233-60NB Nd
    200-38422-15 Hollow cathode lamp, L233-28NQ Ni
    200-38422-69 Hollow cathode lamp, L233-76NU Os
    200-38422-21 Hollow cathode lamp, L233-82NQ Pb
    200-38422-41 Hollow cathode lamp, L233-46NQ Pd
    200-38422-70 Hollow cathode lamp, L233-59NB Pr
    200-38422-20 Hollow cathode lamp, L233-78NU Pt
    200-38422-33 Hollow cathode lamp, L233-37NB Rb
    200-38422-44 Hollow cathode lamp, L233-75NU Re
    200-38422-49 Hollow cathode lamp, L233-45NB Rh
    200-38422-45 Hollow cathode lamp, L233-44NU Ru
    200-38422-24 Hollow cathode lamp, L233-51NQ Sb
    200-38422-71 Hollow cathode lamp, L233-21NB Sc
    200-38422-46 Hollow cathode lamp, L233-34NQ Se
    200-38422-16 Hollow cathode lamp, L233-14NU Si
    200-38422-72 Hollow cathode lamp, L233-62NB Sm
    200-38422-18 Hollow cathode lamp, L233-50NQ Sn
    200-38422-34 Hollow cathode lamp, L233-38NU Sr
    200-38422-35 Hollow cathode lamp, L233-73NU Ta
    200-38422-73 Hollow cathode lamp, L233-65NB Tb
    200-38422-47 Hollow cathode lamp, L233-52NQ Te
    200-38422-17 Hollow cathode lamp, L233-22NU Ti
    200-38422-74 Hollow cathode lamp, L233-81NU Tl
    200-38422-75 Hollow cathode lamp, L233-69NB Tm
    200-38422-19 Hollow cathode lamp, L233-23NU V
    200-38422-36 Hollow cathode lamp, L233-74NU W
    200-38422-76 Hollow cathode lamp, L233-39NB Y
    200-38422-77 Hollow cathode lamp, L233-70NB Yb
    200-38422-23 Hollow cathode lamp, L233-30NQ Zn
    200-38422-37 Hollow cathode lamp, L233-40NU Zr

    Single-Element, for Self-Reversal Method

    P/N Description Measured Element
    200-38456-01 Hollow cathode lamp, L2433-47NB Ag
    200-38456-02 Hollow cathode lamp, L2433-13NB Al
    200-38456-03 Hollow cathode lamp, L2433-33NQ As
    200-38456-04 Hollow cathode lamp, L2433-79NQ Au
    200-38456-05 Hollow cathode lamp, L2433-5NQ B
    200-38456-06 Hollow cathode lamp, L2433-56NB Ba
    200-38456-07 Hollow cathode lamp, L2433-4NQ Be
    200-38456-08 Hollow cathode lamp, L2433-83NQ Bi
    200-38456-09 Hollow cathode lamp, L2433-20NU Ca
    200-38456-10 Hollow cathode lamp, L2433-48NQ Cd
    200-38456-11 Hollow cathode lamp, L2433-27NU Co
    200-38456-12 Hollow cathode lamp, L2433-24NB Cr
    200-38456-14 Hollow cathode lamp, L2433-29NB Cu
    200-38456-15 Hollow cathode lamp, L2433-66NB Dy
    200-38456-16 Hollow cathode lamp, L2433-68NB Er
    200-38456-17 Hollow cathode lamp, L2433-63NB Eu
    200-38456-18 Hollow cathode lamp, L2433-26NQ Fe
    200-38456-19 Hollow cathode lamp, L2433-31NU Ga
    200-38456-21 Hollow cathode lamp, L2433-32NU Ge
    200-38456-22 Hollow cathode lamp, L2433-72NU Hf
    200-38456-24 Hollow cathode lamp, L2433-67NB Ho
    200-38456-26 Hollow cathode lamp, L2433-19NB K
    200-38456-27 Hollow cathode lamp, L2433-57NB La
    200-38456-28 Hollow cathode lamp, L2433-3NB Li
    200-38456-30 Hollow cathode lamp, L2433-12NU Mg
    200-38456-31 Hollow cathode lamp, L2433-25NU Mn
    200-38456-32 Hollow cathode lamp, L2433-42NB Mo
    200-38456-33 Hollow cathode lamp, L2433-11NB Na
    200-38456-35 Hollow cathode lamp, L2433-28NQ Ni
    200-38456-37 Hollow cathode lamp, L2433-82NQ Pb
    200-38456-38 Hollow cathode lamp, L2433-46NQ Pd
    200-38456-40 Hollow cathode lamp, L2433-78NU Pt
    200-38456-43 Hollow cathode lamp, L2433-44NB Ru
    200-38456-44 Hollow cathode lamp, L2433-51NQ Sb
    200-38456-46 Hollow cathode lamp, L2433-34NQ Se
    200-38456-47 Hollow cathode lamp, L2433-14NQ Si
    200-38456-48 Hollow cathode lamp, L2433-62NB Sm
    200-38456-49 Hollow cathode lamp, L2433-50NQ Sn
    200-38456-50 Hollow cathode lamp, L2433-38NB Sr
    200-38456-53 Hollow cathode lamp, L2433-52NQ Te
    200-38456-54 Hollow cathode lamp, L2433-22NB Ti
    200-38456-56 Hollow cathode lamp, L2433-23NB V
    200-38456-58 Hollow cathode lamp, L2433-39NB Y
    200-38456-59 Hollow cathode lamp, L2433-70NB Yb
    200-38456-60 Hollow cathode lamp, L2433-30NQ Zn

    Multi-Element

    P/N Description Measured Element
    200-38422-50 Hollow cathode lamp, L733-201NB Na, K
    200-38422-51 Hollow cathode lamp, L733-202NU Ca, Mg
    200-38422-52 Hollow cathode lamp, L733-203NU Si, Al
    200-38422-53 Hollow cathode lamp, L733-204NQ Fe, Ni
    200-38422-54 Hollow cathode lamp, L733-205NU Sr, Ba